r
DuraStar DS2010
Eastman Chemical Company - Polyester, Thermoplastic

General Information
Product Description

Durastar DS2010 polymer contains a mold release. It has excellent appearance and is nearly water-clear. Its most outstanding features are toughness, chemical resistance, and excellent processing characteristics. DS2010 has very good toughness as shown by Izod impact resistance. Exposure to aromatic oils often causes crazing or actual fracture of many polymer resins, but DS2010 maintains its physical properties when exposed to these oils, and its appearance is virtually unchanged. Easy to process, it flows readily and fills intricate molds. Under existing United States Food and Drug Administration (FDA) regulations, Durastar DS2010 may be used in food contact articles which comply with the specifications and conditions of use in 21 CFR 177.1240. This product is certified to ANSI/NSF Standard 51.

Key Attributes:
- Outstanding Impact Resistance
- Exceptional Clarity
- Fast Drying Times
- Quick Cycle Times
- Chemical Resistance
- Excellent Flow

General  
Material Status
  • Commercial: Active
  • Availability
  • Africa
  • Asia
  • Australia
  • Europe
  • Latin America
  •  
  • Middle East
  • North America
  • Pacific Rim
  • South America
  • Test Standards Available
  • ASTM
  • ISO
  • Additive
  • Mold Release
  • Features
  • Chemical Resistance, Good
  • Clarity, High
  • Cycle (Production), Fast
  • Flow, Good
  •  
  • Food Contact Acceptable
  • Impact Resistance, Good
  • Processability, Good
  • Toughness, Good
  • Uses
  • Appliances
  • Household Goods
  • Sporting Goods
  •  
  • Toys
  • Writing Instruments
  • Agency Ratings
  • FDA 21 CFR 177.1240 1
  • NSF 51
  • Appearance
  • Natural Color
  • Forms
  • Pellets
  • Processing Method
  • Injection Molding
  •  
    ASTM and ISO Properties 2
    Physical
    Nominal Value
    Unit
    Test Method
    Density -Specific Gravity
    1.20
    sp gr 23/23°C
    ASTM D792
    Density
    1.19
    g/cm³
    ISO 1183
    Mold Shrink, Linear-Flow (0.126 in)
    0.0020 to 0.0060
    in/in
    ASTM D955
    Mechanical
    Nominal Value
    Unit
    Test Method
    Tensile Strength @ Yield
    6670
    psi
    ASTM D638
    Tensile Stress at Yield
    6820
    psi
    ISO 527-1, -2
    Tensile Strength @ Break
    7690
    psi
    ASTM D638
    Tensile Stress at Break
    7110
    psi
    ISO 527-1, -2
    Tensile Elongation @ Yld
    5.0
    %
    ASTM D638
    Tensile Strain at Yield
    4.0
    %
    ISO 527-1, -2
    Tensile Elongation @ Brk
    310
    %
    ASTM D638
    Tensile Strain at Break
    210
    %
    ISO 527-1, -2
    Flexural Modulus
    276000
    psi
    ASTM D790
    Flexural Modulus
    254000
    psi
    ISO 178
    Flexural Strength
    9280
    psi
    ISO 178
    Flexural Strength @ Yield
    9720
    psi
    ASTM D790
    Impact
    Nominal Value
    Unit
    Test Method
    Notched Izod Impact     ASTM D256
    (-40 °F)
    1.12
    ft-lb/in
     
    (73 °F)
    6.93
    ft-lb/in
     
    Notched Izod Impact Strength     ISO 180
    (-40 °F)
    3.00
    ft-lb/in²
     
    (73 °F)
    14.1
    ft-lb/in²
     
    Unnotched Izod Impact     ASTM D256
    (-40 °F)
    No Break
    ft-lb/in
     
    (73 °F)
    No Break
    ft-lb/in
     
    Instrumented Dart Impact     ASTM D3763
    (-40 °F)
    Energy at Peak Load: 425
    in-lb
     
    (73 °F)
    Energy at Peak Load: 398
    in-lb
     
    Multi-Axial Instrumented Impact Energy     ISO 6603-2
    (-40 °F)
    Energy to Peak Force: 40.6
    ft-lb
     
    (73 °F)
    Energy to Peak Force: 52.4
    ft-lb
     
    Hardness
    Nominal Value
    Unit
    Test Method
    Rockwell Hardness (R-Scale)
    105
     
    ASTM D785
    Thermal
    Nominal Value
    Unit
    Test Method
    DTUL @66psi - Unannealed
    163
    °F
    ASTM D648
    HDT B (0.45 MPa) Unannealed
    163
    °F
    ISO 75B-1, -2
    DTUL @264psi - Unannealed
    149
    °F
    ASTM D648
    HDT A (1.80 MPa) Unannealed
    151
    °F
    ISO 75A-1, -2
    Electrical
    Nominal Value
    Unit
    Test Method
    Surface Resistivity
    1.0E+17
    ohms
    ASTM D257
    Volume Resistivity
    1.0E+17
    ohm-cm
    ASTM D257
    Dielectric Strength  3
    422
    V/mil
    ASTM D149
    Dielectric Constant     ASTM D150
    (1000 Hz)
    2.600
     
     
    (10000 Hz)
    2.600
     
     
    (100000 Hz)
    2.500
     
     
    (1E+6 Hz)
    2.500
     
     
    Dissipation Factor     ASTM D150
    (1000 Hz)
    0.0060
     
     
    (10000 Hz)
    0.012
     
     
    (100000 Hz)
    0.015
     
     
    (1E+6 Hz)
    0.015
     
     
    Arc Resistance
    123
    sec
    ASTM D495
    Flammability
    Nominal Value
    Unit
    Test Method
    Flame Rating - UL (0.118 in)
    V-2
     
    UL 94
    Optical
    Nominal Value
    Unit
    Test Method
    Transmittance
    89.0
    %
    ASTM D1003
    Haze
    0.30
    %
    ASTM D1003
    Additional Properties

    Comparative Tracking Index, ASTM D3638: 700V
    Regular Transmittance, ASTM D1003: 89%
    Total Transmittance, ASTM D1003: 91%

     
    Processing Information
    Injection
    Nominal Value
    Unit
    Drying Temperature
    158
    °F
    Drying Time
    3.0
    hr
    Processing (Melt) Temp
    482 to 554
    °F
    Mold Temperature
    59.0 to 86.0
    °F
     
    Notes
    1 When used unmodified for the manufacture of food contact articles, DuraStar DS2010 will comply with Food Additive Regulations FDA 21 CFR 177.1240 under the U.S. Food, Drug and Cosmetic Act. Such uses are subject to good manufacturing practices and any other limitations which are part of the statute or regulations. These should be consulted for complete details.
    2 Typical properties: these are not to be construed as specifications.
    3 Method A (Short-Time)
       
     

    Makes no representation or warranty of any kind, express or implied, with respect to this product, as to merchantability, Fitness for particular purpose or otherwise. The data listed represents average values and are believed to be reliable, They are given for information; no guarantee of their accuracy is made, however, and the product is sold upon condition that purchasers shall make their own test to determinate the characteristics of the product and the suitability of the product for their particular process.